APPLICATIONS / DESALINATION

Dechlorination and reverse osmosis membrane protection

In reverse osmosis desalination plants, the quality of the water feeding the membranes is an essential parameter for maintaining their performance and service life.

When residual chlorine or other oxidising species are present upstream of membranes that are sensitive to oxidation, a dechlorination stage is required to reduce their concentration before the water enters the reverse osmosis units.

Sodimate designs solutions for the storage, dosing, solution preparation and transfer of powder reagents used for this stage, particularly sodium metabisulphite.

Why protect reverse osmosis membranes?

Membranes are a central component of the reverse osmosis process. Maintaining their performance depends directly on the characteristics of the feed water and on controlling the operating conditions of the installation.

Upstream of reverse osmosis, various treatments may be applied to the water to control suspended solids, biological activity and certain compounds that may affect the membranes.

Chlorine may in particular be used during certain pretreatment stages to control biological growth. However, the polyamide reverse osmosis membranes commonly used in desalination plants are sensitive to oxidising agents.

Residual chlorine must therefore be controlled before the water enters the membranes in order to limit their exposure to oxidation and preserve their separation properties.

Why dechlorinate water before reverse osmosis?

Dechlorination consists of reducing residual chlorine present in the water before it passes through the membranes when these are sensitive to oxidising agents.

This stage takes place after treatments requiring chlorination and before the water enters the membranes.

The objective is to control the chemical conditions of the water in order to protect the membranes against exposure to oxidising agents that could progressively impair their performance.

The required level of dechlorination and the amount of reagent needed depend in particular on:

  • residual chlorine concentration;
  • water characteristics;
  • flow rate to be treated;
  • reagent used;
  • membrane manufacturer's requirements; and
  • plant operating conditions.

Pretreated water

Residual chlorine

Injection of dechlorination reagent

Reaction

Residual chlorine and/or oxidation-reduction potential control

Reverse osmosis

Sodium metabisulphite for dechlorination

Sodium metabisulphite (Na₂S₂O₅) is a reagent used in water treatment processes for dechlorination upstream of certain reverse osmosis membranes.

Before injection, sodium metabisulphite in powder form is prepared as an aqueous solution.

The resulting solution provides a reducing agent that reacts with the chlorinated species present in the water. The dosage must be adapted to the amount of oxidant to be neutralised and to the process operating conditions.

Consistent reagent feeding and controlled concentration of the prepared solution therefore contribute to maintaining the required conditions upstream of the membranes.

How is sodium metabisulphite prepared and dosed?

The use of sodium metabisulphite from a powder product involves several stages to convert the solid reagent into a solution suitable for injection into the process.

The reagent is first stored in a container suited to the plant's consumption requirements. It is then discharged and dosed before being introduced into a solution preparation tank supplied with water.

Agitation ensures dissolution and homogenisation of the solution before it is transferred to the injection point.

The reagent handling process generally includes:

  • sodium metabisulphite storage;
  • discharge;
  • dosing;
  • dissolution in water;
  • solution homogenisation; and
  • transfer to the injection point.

Sodium metabisulphite storage

Discharge and dosing

Water supply

Solution preparation

Agitation / homogenisation

Transfer

Injection upstream of the membranes

Key parameters for dechlorination

The effectiveness of dechlorination depends on controlling reagent dosage and adapting it to the actual operating conditions of the installation.

The quantity of solution injected must in particular be adapted to the residual chlorine concentration and the water flow rate to be treated.

Solution preparation also requires several parameters to be controlled:

Solution concentration

Achieve a concentration suited to the injection flow rate and process requirements.

Reagent dosing

Ensure consistent metabisulphite feeding during preparation.

Solution homogeneity

Ensure complete dissolution and a homogeneous concentration before injection.

Injection flow rate

Adapt the quantity injected to the operating conditions of the installation.

Dechlorination control

Ensure that the required conditions at the membrane inlet are met.

The operating values must be defined taking into account the water characteristics, treatment objectives and membrane supplier's recommendations.

Equipment used for sodium metabisulphite handling

Consistent reagent preparation and feeding contribute directly to reliable dechlorination.

Depending on plant capacity and supply method, Sodimate solutions can provide:

  • sodium metabisulphite storage;
  • discharge and dosing;
  • solution preparation;
  • maintenance of a homogeneous solution; and
  • transfer to the injection system.

This equipment can be integrated into a complete reagent preparation system or used for a specific process stage.

Main challenges of dechlorination and membrane protection

Protecting the membranes requires consistent control of water characteristics and of the dechlorination reagent handling process.

Residual chlorine variability

Adapt treatment to the actual characteristics of the water feeding the installation.

Metabisulphite dosing

Maintain a quantity of reagent suited to process requirements.

Solution preparation

Ensure a homogeneous and reproducible concentration.

Dechlorination control

Ensure that the required water conditions are achieved before it enters the membranes.

Membrane protection

Limit membrane exposure to oxidising agents in order to maintain performance.

Continuity of operation

Ensure consistent reagent preparation and feeding.

FAQ on dechlorination and reverse osmosis membrane protection

Why must water be dechlorinated before reverse osmosis membranes?

Certain reverse osmosis membranes, particularly polyamide membranes, are sensitive to oxidising agents. When residual chlorine is present in the pretreated water, its concentration must be reduced before the water enters the membranes, in accordance with the conditions defined for their operation.

What is the role of sodium metabisulphite in desalination?

Sodium metabisulphite is used as a reducing agent to neutralise residual chlorine before reverse osmosis. It is generally prepared as a solution before being injected into the water to be treated.

How is sodium metabisulphite prepared before injection?

Sodimate preparation tanks can be used to prepare a homogeneous sodium metabisulphite solution before it is transferred to the injection point.

How is the amount of sodium metabisulphite to be injected determined?

The required amount depends in particular on the residual chlorine to be neutralised, the water flow rate, water characteristics and plant operating conditions. The dosage must be defined according to the dechlorination objectives and the requirements applicable to the membranes.

Where is the dechlorination reagent injected?

The reagent is injected upstream of the reverse osmosis membranes, after the pretreatment stages requiring the presence of an oxidising agent. The injection point and mixing conditions must ensure the required dechlorination before the water enters the membranes.

Desalination projects

Sodimate solutions are integrated into desalination plants for the preparation and dosing of reagents used at different treatment stages.

Each project illustrates how the equipment is adapted to the reagent characteristics, process requirements and operating constraints specific to the installation.

Looking for a solution for dechlorination and membrane protection?

Each desalination plant presents specific constraints related to the quality of the pretreated water, the membranes used, the reagents involved and the operating conditions.

Sodimate teams support you in assessing sodium metabisulphite handling requirements, sizing the storage, dosing and solution preparation equipment, and integrating it into your installation.

This site uses cookies to measure audience and improve your experience. Cookies